2YM15
2YM15
12/05
Marine Installation Manual - Volume 2
2YM15-5
© 2007 Yanmar Marine International
Air Intake and Exhaust Specifications
Figure - 1
Alarm System Specifications
Parameter Data
Minimum Engine
Room Fresh Air
Exchanges (Ventilator
Capacity)
5.5 m
3
/min.
(194.23 cu ft/min.)
Maximum Air Inlet
Depression
4.0 kPa
408 mmAq
(16.06 in.Aq)
Maximum Back
Pressure
30 kPa
3059 mmAq
(0.31 kgf/cm
2
)
Maximum Exhaust
Gas Temperature
(measured within
250 mm [9.8 in.] of
exhaust manifold
inlet)
500°C
(932°F)
EPA Exhaust Test
Port Size
Location: Service Tool
G 1/4 - 19 BSPP*.
Refer to Figure - 1.
Maximum Engine
Room Ambient
Temperature
60°C
(140°F)
Exhaust Pipe Outer
Diameter Connection
51.0 mm
(2.008 in.)
* NOTE: Port / Service Tool NOT finalized. Back
pressure measured from EPA test port located
on the service tool. CAUTION! Test ports are
British Standard Pipe Parallel (BSP) not
National Pipe Thread (NPT). BSP and NPT
threads are not compatible due to the thread
pitch. Mixing can cause thread damage. Refer
to Installation Manual Volume 1, Appendix C.
Parameter Data
Coolant Alarm Switch
Operating
Temperature
ON:
93 - 97°C
(199.4 - 206.6°F)
OFF:
88 - 93°C
(190 - 199°F)
Engine Oil Alarm
Switch - Low Oil
Pressure
9.8 - 29.4 kPa
(1.43 - 4.27 psi)
4XC3 (0.12)
4XØ9 (0.35)
90 (3.54)
72 (2.84)
Ø 38
(1.5)
3 (0.12)
20 (0.79)
10
(0.39)
62 (2.44)
44 (1.73)
25
6.3
6.3
6.3
Unit: mm (in.)