6. Periodic Inspections and Maintenance
23
EN
Use Compressed Air (0.5~1 Bar) from
main system, 12 V portable compres-
sor or from portable hand pump or foot
pump.
Option 2: Using Compressed air
with help from a portable hand
pump or foot pump
(1) Install a one-way (non return) valve
in the pressure line (connected to
the top cover). This is done to main-
tain the pressure during use of the
pump.
(2) Connect the hand pump or foot
pump with the pressure line to the
adapter joint on the top as shown
above.
(3) With the system now connected,
pump out the oil until empty. The
first 0.9 liter will take approx. 3 min-
utes. The second part takes more
time as mostly air will be pumped
out; this will take approx. 12 min-
utes.
6.2.1.4 Using Yanmar Pump
First follow steps (1), (2), (3) on page 22
and step (1) on page 22
Connect the hand pump with hoses as
shown above, and start pumping.
Be aware that oil has to flow down through
narrow parts and then up again.
Therefore, during this procedure, at first
suction pressure will be high and pumping
will be hard. A few minutes waiting in be-
tween will help. After taking out about 0.9
liter of oil, mostly you will pump out air, but
continuous pumping is necessary.
Though approx. 100-200 ml of old oil will
remain in the drive unit, in this case, it is no
problem to fill-up with the new oil for main-
tenance.
The hand pump (p/#:28210-000080) and
rubber hose (p/#:196440-92970) are avail-
able from Yanmar, and are optional parts
for SD50/-4T. Or any type of hand pump or
rubber hose (Inner diameter ø14-16 mm)
available from the hardware shop, are us-
able.
A One-way valve
B Adapter joint screwed in cover
C Simple foot pump
003454-00E
B
A
C