Yanmar BY series Spezifikationen Seite 68

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 127
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 67
ENGINE OPERATION
BY Series Operation Manual 61
SHUTTING DOWN THE
ENGINE
Under normal operating conditions, shut
down the engine by turning the key switch
to OFF.
There may be a delay of up to 3-seconds
after turning the key to OFF. This is normal
and allows the ECU computer to store
data.
Emergency Shut Down
1. Ensure lanyard is connected to the
emergency stop switch.
2. Attach the lanyard to a secure place on
the operator’s clothing or life vest - not
where it might tear away.
IMPORTANT
Do not cut or re-tie the lanyard. If it
is too long, shorten it by knotting
or looping it.
Test the emergency engine shut
off switch before each outing.
3. Disconnecting the clip from the stop
switch will stop the engine.
CHECKING THE ENGINE
AFTER OPERATION
Check that the key switch is in the OFF
position and battery master switch (if
equipped) is OFF.
Fill the fuel tank. Make sure that the fill
cap and the area around the fill opening
are clean to avoid contamination of the
fuel.
Close seawater cock(s).
If there is a risk of freezing, check that
the cooling system contains enough
coolant. See Engine Coolant on
page 49.
If there is a risk of freezing, drain the
seawater system. See Drain Seawater
Cooling System on page 108.
CAUTION
Be sure to close the seacock.
Neglecting to close the seacock
could allow water to leak into the
boat and may cause it to sink.
0000152en