10. Remove the key from the key switch
and cover the key switch with the
moisture cap (if equipped).
DRAINING THE COOLING
SYSTEM
In cold temperatures or before long-term
storage, be sure to drain the seawater from
the cooling system.
1. Put a pan under the seawater drain
cocks.
2. Loosen the drain cock at the side of the
thermostat cover and drain the water
from the inside.
3. Loosen the three bolts holding the side
cover (Figure 1, (7)) of the seawater
pump. Remove the cover and drain the
seawater from the pump body
(Figure 1, (4)). Reinstall the cover and
retighten the bolts when finished.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
0005887
Figure 1
1 – Cam
2 – Inlet
3 – Outlet
4 – Seawater Pump Body
5 – Impeller
6 – Gasket
7 – Side Cover
4. Close the drain cock.